Clean agent based fire suppression system,
FM-200 gas fire suppression system,
HFC227ea Gas fire suppression system,
Novec-1230 gas fire suppression system,
FK-5-1-12 Gas fire suppression system,
CO2 Gas fire suppression system,
Kitchen Fire suppression system,
Vehicle Fire suppression system.
₹ 300000/Set Get Latest Price
Type | Fire Alarm System |
Fire Suppression Type | Fire Extinguisher |
Capacity | ANY |
Automation Grade | Automatic |
Usage/Application | GAS FLOODING SYSTEM |
Extinguishing Agent | CLEAN AGENT AND CO2 |
Brand | FIRE ENGINEERING TECHNOLOGY |
Color | RED |
Cylinder Height | AS PER CAPACITY |
Design | AS PER NFPA |
Gaseous fire suppression is a term to describe the use of gases and chemical agents to extinguish a fire. These Agents are governed with different standards and regulations in the world. The system typically consists of the agent, agent storage containers, agent release valves, fire detectors, fire detection system (wiring control panel, actuation signalling), agent delivery piping, and agent dispersion nozzles. | ||||||||||||
Gas Flooding System features: | ||||||||||||
|
||||||||||||
Designed to withstand every climatic conditions, these devices are widely used in following area of applications: |
||||||||||||
|
₹ 125000/Piece Get Latest Price
Type | Wired |
Usage/Application | Truck |
Range | 2 CUBIC MTR |
Brand | FET |
Screen Size | 2.5 inch |
Material | DCP POWDER |
Model Name/Number | AFDSS |
Warranty | 12 MONTHS |
Color | RED |
Battery | 24V |
Vehicle Suppression Systems
February 24, 2022
Vehicle suppression systems keep large vehicles safe in case of fire.
Large construction vehicles and buses are a significant investment for private firms and public transit authorities. Replacing a large construction vehicle consumed by fire is a serious financial setback. Transit authorities need to provide reliable, safe transportation. To protect these assets and the people who use them, install a vehicle suppression system.
What is a Vehicle Suppression System?
A vehicle suppression system is a fire extinguishing system installed in a vehicle engine compartment or anywhere else that presents a risk of fire. These systems are designed to discharge a dry or wet chemical extinguishing agent. They can use spot-type heat detectors or linear detection tubing. The type that is installed will depend on the vehicle and its intended use.
Different Types of Vehicle Suppression SystemsVehicle suppression systems can be dry, wet, or a dual agent system that utilizes both wet and dry chemical agents. Dry systems deprive the fire of oxygen, while wet systems cool the fire. A dual system combines these elements for a more thorough suppression of the fire. A Fireline professional can help determine which system is best for you based on the vehicle type and intended use.
₹ 105000/Set Get Latest Price
Type of Fire Detectors | Heat detector |
Material | Mild Steel (MS) |
Operating Voltage | 230V AC |
Operating Current | 5 AMP |
Operating Temperature | 100 |
Brand | FIRE ENGINEERING TECHNOLOGY |
Relay Outputs | Alarm Relay, Supervisory Relay, Trouble Relay |
Certification | UL/ FM/ LPCB/ CE |
Dimensions | CUSTOMIZE |
Weight | 1.3 KG |
Control Keys | Evacuate, Mute Buzzer, System Reset |
Introduction of Fire Detection and Alarm System
Fire detectors are designed to detect one or more of the three characteristics of fire-smoke, heat and flame. Besides it every fire detection system must include manual call points (break glass), so that in the event of fire can be of immediate help.
During a fire importance of activation of the occupants through alarm or bell is of at most vital and this can performed through alarm system.
Microprocessor based addressable analogue type fire alarm and detection system to be used for various building/areas to detect and provide alarm signal in the main fire alarm panel to be located in the central control room. Fire alarm will be repeated in a repeater alarm panel in the fire station.
Main fire alarm panel annunciation shall be located in the control building. A repeater panel shall be provided in the fire station. Total no of annunciation shall be based on the specific plant requirement.
One (1) siren of 10 Km range is envisaged to provide warning in the event of fire.
In addition to it, PLC panel shall be provided at fire pump house and foam pump house.
₹ 37000/Piece Get Latest Price
Fire Fighting System Type | Fire Suppression Systems |
Packaging Type | Set |
Capacity | 1-9 Kg |
Usage/Application | Electrical Fire, Kitchen Fire, Vehicle Fire etc |
System type | Pre-Engineered System |
Brand | FIREFINDER |
Material | Mild Steel |
Environment Temp | 100-120 DEGREE |
Fire Suppression Type | Fire Extinguisher, Cylinder |
Certification | UL/ LPCB/ CE |
The principle of all Tube Fire Suppression Systems is a simple self-activating system that offers the widest versatility, which results in an excellent cost / performance balance. Trace Tube Systems can be used in a range of applications, with the principals remaining the same; Stop The Fire Where It Starts.
Electrical Panels & Switch-gear Fire Suppression | Tumble Dryers | Plant & Machinery fire suppression | Fume Cabinet fire suppression | CNC & EDM Machinery | Wind Turbines Agricultural Machinery | Cars/Vans/Trucks – including Motor Sport | Rail & Dockside
FireFinder Quickly & Accurately: These systems use linear detection tubing which is installed throughout the asset it’s covering & can not only quickly and accurately detect a fire but also suppress it before it can damage adjacent components.
Simple Solution To A Complex Fire Problem: These systems do not need complicated electronic detectors or panels and operate simply pneumatically.This alleviates the need for separate power supplies or battery backups and also makes the entire system fail safe with minimal moving parts. We offer a choice of extinguishant agents such as Novec, CO2, Powder, FM200, some of which can be used safe in the knowledge that they will not damage the electrical components or leave a residue.
₹ 4500/Kg Get Latest Price
Fire Fighting System Type | Fire Suppression Systems |
Packaging Type | Set |
Capacity | Any as per requirement |
Usage/Application | Electrical Panels & server area |
System type | Clean Agent Suppression System |
Brand | AR Suppression |
Material | As required |
Environment Temp | 21 |
Fire Suppression Type | Pipeline, Fire Extinguisher, Cylinder |
Certification | UL |
FK-5-1-12 Gas supression or FK-5-1-12 fire pritection system is a kind of gas flood system.
FK 5-1-12 is a chemical agent designed and manufactured for Fire Suppression applications. FK 5-1-12 has zero Ozone Depletion Potential making it a replacement for other chemical agents used in Fire suppression like HFC227ea. FK 5-1-12 can be used in manned area and are not harmful to human being.
The importance of erection, testing and commissioning are overlooked in many projects while installing and fixing Clean Agent Gas Fire Suppression System. It is a very common practice to fabricate the Clean Agent Gas Fire Suppression System including the manifold at site.
It is very difficult to ensure the proper integration of entire cylinder bank assembly which involves very high pressure and critical instrumentation such as solenoid connection, pneumatic actuation to ensure proper functioning of the entire system.
bala-wa -5112 Clean Agent Fire Suppression-High Pressure fixed installation clean agent gas cylinder banks are fully pre-assembled,integrated & tested for its proper operation at the factory itself. Customers and consultants may strongly recommend to use pre-assembled & tested bala-wa-5112 cylinder bank assembly.
₹ 55000/Set Get Latest Price
Alarm Volume | 100 DB |
Relay Outputs | Supervisory Relay |
Alarm Indication Type | Audeo Visual |
Control Keys | Mute Buzzer, System Reset, Evacuate |
Protection Category | Detection and suppression |
Protection Class | B & C |
Standard | NFPA 2001 |
A fire suppression system combines devices and equipment to detect and combat fires, often through water, gas, or other chemicals. These systems are engineered to activate automatically upon detecting a fire, deploying suppressants to halt the spread of flames and mitigate damage.
Unlike a simple fire extinguisher that requires manual operation, fire suppression systems are typically integrated with smoke or heat detectors and alarm systems. When a fire is detected, the system dispenses its suppressant material, such as water, foam, or gas, to quench it. In high-risk commercial environments like server rooms or kitchens, these systems prioritize human safety and the protection of valuable assets.
₹ 55000/Piece Get Latest Price
Packaging Type | Set |
System type | Pre-Engineered System |
Usage/Application | Industrial |
Brand | AR SUPPRESSION |
Material | Metal Alloy |
Environment Temp | 21 |
Fire Suppression Type | Fire Extinguisher, Cylinder, Pipeline |
Certification | UL & CE |
Operating Temperature Limit | 100-120 |
Working Pressure | 15 BAR |
Automatic fire suppression systems control and extinguish fires without human intervention. Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression.
Anil Mishra (Owner)
Fire Engineering Technology
Plot No. 71, Sewak Park
Uttam Nagar, New Delhi - 110059, Delhi, India