- Home
- ยป
- Products & Services
- »
- Automatic Fire suppression alarm system
Automatic Fire suppression alarm system
Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different applications being used today. Of these, there are some that are still in use but are no longer legal to manufacture and produce.
Clean agent based fire suppression system,
FM-200 gas fire suppression system,
HFC227ea Gas fire suppression system,
Novec-1230 gas fire suppression system,
FK-5-1-12 Gas fire suppression system,
CO2 Gas fire suppression system,
Kitchen Fire suppression system,
Vehicle Fire suppression system.
Wind Turbine Fire Suppression System
Product Brochure
Usage/Application | Industrial |
Type | Fire Suppression Systems |
Packaging Type | Set |
Capacity | as per design requirement |
System type | Pre-Engineered System |
Brand | FET |
Material | Metal Alloy |
Environment Temp | 21 |
Fire Suppression Type | Pipeline, Fire Extinguisher, Cylinder |
Certification | CE & UL |
When addressing fire protection for wind turbines (prevention as well as suppression), the best practices include both passive and active fire protection measures.
Passive fire protection is pretty much what the term “passive” implies, i.e., it is fire protection which, once implemented, does not require active action. Some examples of passive fire protection of wind turbines are:
-
Choosing noncombustible materials during construction (in this case, specifically, the nacelle)
-
Selecting/using noncombustible hydraulic and lubrication oils
-
Compartmentalizing the nacelle area
-
Installing lightning protection systems
-
Installing systems to monitor the conditions of components/equipment
So what are the best, most effective systems to use once a fire has been ignited in a wind turbine?
No matter the extent of passive fire protection measures which are employed, one can never assume that a fire will not occur. And once a fire does occur, immediate measures must be taken, particularly before a very small, undetected, and remote fire evolves into one which significantly damages or totally destroys a wind turbine.
In the case of a wind turbine fire (as with many other industrial fires), active fire protection involves:
-
Instant fire detection
-
Instant triggering of fire alarm systems
-
Quick-acting fire suppression systems
The most widely used and most effective fire suppression systems in wind turbines are aerosol systems. A connected smoke/heat detector sends a signal to the aerosol system which immediately activates a discharge of the fire extinguishing agent. The fire is extinguished almost as quickly as it started, minimizing both the risk of extensive property loss, as well as potential loss of life.
All wind turbines should be equipped with an intelligent fire detection and clean agent suppression system. The cost of having such a system is minimal; yet, in the event of a fire, the cost of not having such a system would most likely be catastrophic.
Therefore, a proactive approach to wind turbine fire protection is essential. The simple, non-obtrusive installation of a proven detection and suppression system is a must for these confined, remote, and costly assets.
Fm 200 Gas Suppression System
Product Brochure
Type | Fire Suppression Systems |
Capacity | Any |
Usage/Application | Electrical & Server Equipments |
Color | REd |
Certification | UL |
Body Material | MS/ SS |
Installation Services Required | Yes |
Size/Dimension | ANy |
Automation Grade | Automatic |
Design | NFPA 2001 |
FM-200™, also commonly known as HFC-227ea, is a clean agent fire suppressant for Class A, B, and C fires and meets NFPA Standard 2001 Clean Agent Fire Extinguishing Systems. Clean agents are fast and effective in suppressing fires, are safe in occupied spaces, and do not leave a residue.
FM-200™ suppresses fire by disrupting the fire triangle. The fire triangle is made up of heat, oxygen, and a fuel source, and by removing one of these elements, the fire is extinguished. FM-200™ removes the heat or free radicals, which interferes with the fire triangle's chemical reaction to extinguish the fire. Clean agent fire suppression systems, like ones using FM-200™, can achieve fire extinguishing concentrations in 10 seconds or less.
Advantages:
- FM-200™ is a clean agent that is safe around people; therefore, FM-200™ fire suppression systems are safe to install in occupied spaces.
- When an FM-200™ fire suppression system activates to put out a fire, no residue is left behind, and it is safe for equipment, electronics, and machinery.
- Compared to other clean agents like 3M™ Novec™ 1230 Fire Protection Fluid, FM-200™ is a slightly more cost-effective option.
- Because of the small amount of FM-200™ required to suppress a fire, smaller or fewer cylinders are needed when compared to other agents like 3M Novec 1230 fluid.
SPECIAL EXTINGUISHING SYSTEMS
Product Brochure
Fire Fighting System Type | Fire Suppression Systems |
Capacity | ANY |
Usage/Application | MICRO & MACRO ENVIROMENT |
Color | RED |
Certification | UL/ LPCB/ VDS/ CE |
Body Material | SS/ MS/ CARBON STEEL |
Installation Services Required | YES |
Size/Dimension | AS REQ |
Automation Grade | AUTOMATIC |
Design | NFPA 2001 |
CLEAN AGENT FIRE SUPPRESSION SYSTEMS : A Fire Suppression System whose means of extinguishment does not cause damage in addition to that which was caused by the fire itself.
Fire Protection Systems : Safety Occupants, respondents, surroundings, Damage Control Buildings, equipment, data Business, operations, revenue.
Special Hazards Data processing Telecommunications Rooms and Subfloors : Special HazardsData processing, Rooms and Subfloors, Tape vaults, Robotic storage units, Telecommunications, Switch facilities, Cell sites, Battery storage.
Special Hazards Healthcare Historic/Cultural Properties : Special Hazards Power Generation, Turbine enclosures, Generator sets, Electrical/motor control rooms, Marine, Machinery spaces, Pump or generator rooms, Cargo holds.
Special Hazards Industrial Applications Specialty Applications : Special Hazards Industrial ApplicationsProcess control rooms, Motor control rooms, Flammable liquid storage, Specialty Applications, In-cabinet, CNC Machines, Performance vehicle, Fume Hoods.
Special Hazards Systems : Five types of systems Foam, Carbon Dioxide, Dry Chemical, Water Mist, Clean Agents.
Clean Agent Systems Waterless technology - objectives : Clean Agent Systems Waterless technology - objectives , Detect and suppress fires rapidly, No additional damage to equipment, Eliminate down time for unaffected equipment, Environmentally friendly, Require no clean-up, Safe for Personnel.
Gas flooding system
Product Brochure
Fire Suppression Type | Pipeline |
Fire Fighting System Type | Fire Suppression Systems |
Capacity | any |
Usage/Application | Electrical & Server Area |
Extinguishing Agent | Clean agents & CO2 |
Brand | FIRE ENGINEERING TECHNOLOGY |
Color | RED |
Cylinder Height | as req |
Design | NFPA 2001 |
Discharge Range | 1 mtr |
The Gas Suppression system typically consists of the agent, agent storage containers, agent release valves, fire detection and control system (wiring control panel, actuation alarming), agent delivery piping, and agent dispersion nozzles. The agent may be delivered by means of solid propellant gas generators that produce inert gas.
Server Room Gas Suppression System
Product Brochure
Type | Cylinder |
Capacity | 5 kg |
Brand | Fire Engineering Technology |
Packaging Type | Box |
Usage/Application | Commercial |
Material | Carbon Steel |