This Linear Pneumatic Heat Detection tube when installed in a small enclosure, filled with fire suppressing agent and pressurised with Nitrogen, will detect heat/fire in the range of 85°C to 135°C . On impingement with this heat/fire, the tube ruptures at the hottest point, forming a dispensing Nozzle, from which the pressurised agent is discharged instantly directly on the source of the heat/fire extinguishing it instantly and flooding the area with the agent, thereby mitigating any spread or reignition of fire.

By utilising a pressure switch attached to the tube via an EOL on one end and interfacing with any existing FACP or Audio-Visual Alarm unit the activation of the unit can be annunciated, or functions like tripping the power supply or switching on/off ventilation etc. can be also achieved.

This automatic Fire detection & suppression is a standalone reliable and simple system that doesn’t require other hard wares or power input to activate and requires no maintenance. The system pressure can be monitored by visual check of the provided pressure gauge.

KEY FEATURES

  • Special Formulated material designed to function in Harsh and reactive environments.
  • Formulation designed to prevent surface damage when exposed to or installed on Galvanised metal/equipment’s.
  • Special Formulation prevents gradual permeation of pressurising agent over period of time, adding to its 100% reliability.
  • Non-Destructive Tested to withstand pressure max up to 120 Bar.
  • Low moisture and water absorption ratios.
  • Chemically resistive to most common chemicals
  • Compatible with all Inert, Low pressure and High-Pressure Agents
  • Utilised and installed as standalone linear heat detector and suppression unit.
  • Compatible Fire suppressant Agents- All Clean Agents, (FK5112, HFC227ea, FE36) All Dry Chem. Powder
Request CallBack
End of Line Adaptor with Pressure Gauge & NRV
Get Best Quote

End of Line Adaptor with Pressure Gauge & NRV

Approx. Price: Rs 2,850 / SetGet Latest Price
Product Details:
Minimum Order Quantity10 Set
TypeDirect
Fire Extinguisher TypeModular Automatic Type
Capacityall
Fire ClassC
ApplicationElectrical Panel/ Enclosure
MaterialMetal alloy
Usage/ApplicationEnd of the tube for N2 pressurerisation
Environment Temp68
Certificationce
End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives.

Additional Information:
  • Item Code: EOLA
  • Production Capacity: 500/ Month
  • Delivery Time: 2-3 weeks
Yes! I am Interested
Request CallBack
  • Fire Fighting System AMC
  • Fire Fighting System AMC
  • Fire Fighting System AMC
  • Fire Fighting System AMC
Fire Fighting System AMC
Get Best Quote

Fire Fighting System AMC

Approx. Price: Rs 5,000 / PackGet Latest Price
Product Details:
Service TypeAMC Service
Service Duration1-2 Days
Pressure15-20 BAR
Service LocationPan India
All Type Fire Fighting AMC

Yes! I am Interested
Request CallBack
  • Self-Activating Fire Suppression System Tube
  • Self-Activating Fire Suppression System Tube
  • Self-Activating Fire Suppression System Tube
  • Self-Activating Fire Suppression System Tube
  • Self-Activating Fire Suppression System Tube
  • Self-Activating Fire Suppression System Tube
Self-Activating Fire Suppression System Tube
Get Best Quote

Self-Activating Fire Suppression System Tube

Approx. Price: Rs 18,500 / UnitGet Latest Price
Product Details:
Fire ClassA,B & C
MaterialPolymer Tube
BrandFire Engineering Technology/ Autofirex/ Blazecut
Capacity0.25 Kg
Fire Extinguisher Typeclean agent Gas
System TypeCylinder less fire suppression system
GasUL Approved
ApplicationsCar/ Truck/ Mining vehicles
SIze17x15 mm
Length1 Mtr

This Linear Pneumatic Heat Detection tube when installed in a small enclosure, filled with fire suppressing agent and pressurised with Nitrogen, will detect heat/fire in the range of 85°C to 135°C . On impingement with this heat/fire, the tube ruptures at the hottest point, forming a dispensing Nozzle, from which the pressurised agent is discharged instantly directly on the source of the heat/fire extinguishing it instantly and flooding the area with the agent, thereby mitigating any spread or reignition of fire.

By utilising a pressure switch attached to the tube via an EOL on one end and interfacing with any existing FACP or Audio-Visual Alarm unit the activation of the unit can be annunciated, or functions like tripping the power supply or switching on/off ventilation etc. can be also achieved.

This automatic Fire detection & suppression is a standalone reliable and simple system that doesn’t require other hard wares or power input to activate and requires no maintenance. The system pressure can be monitored by visual check of the provided pressure gauge.

  • Self contained,Reliable,24 x7 Automatic Fire Detection & Protection for equipment against Fires.
  • Fast-Detection & Suppression of fire in seconds, mitigating losses due to equipment damage and downtime
  • Multiple Detection points-AutoFireX Proprietary Fire Detection Tube (FDT)acts as a Linear Pneumatic Heat detector can detect fire throughout its installed length
  • No External Power required to activate the system. No “False Alarm” or Discharges AutoFireX systems only activate in the event of an actual fire/heat impingement.
  • Post Discharge – Systems utilizing Clean suppression agents require no post-discharge clean up.
  • Easy to install in any new or existing Equipment’s (Electrical Panels, server rack etc.) and requires no power to operate.
  • Environmentally Friendly – Low Pressure systems utilizing UL certified Clean Agents is not harmful to equipment or the environment.
  • Interface Options -AutoFirex System comes with various options to initiate activities like Annunciation, shut on or shut of Power supply, ventilation, interface and monitoring through BMS, SCADA etc.
  • Low Maintenance-AutoFireX systems do not interfere with installation or maintenance of equipment and can also be retrofitted to existing equipment’s