Fire Engineering Technology
Fire Engineering Technology
Uttam Nagar, New Delhi, Delhi
GST No. 07AADFF6834G1ZG
Call 08048016259 94% Response Rate
Send E-mail

Novec 1230 Fire System

Gaseous fire suppression, also called clean agent fire suppression, is a term to describe the use ofinert gasesand chemical agents to extinguish afire. These agents are governed by theNational Fire Protection Association(NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere. The system typically consists of the agent, agent storage containers, agent release valves,fire detectors, fire detection system (wiring control panel, actuation signaling), agent delivery piping, and agent dispersion nozzles. Less typically, the agent may be delivered by means ofsolid propellantgas generatorsthat produce either inert or chemically active gas.

There are four means used by the agents to extinguish a fire. They act on the "fire tetrahedron":

  • Reduction or isolation of fuel. No agents currently use this as the primary means of fire suppression.
  • Reduction of heat. Representative agents:Clean agent FS 49 C2(NAF S 227, MH227, FM-200),Novec 1230,pentafluoroethane(NAF S125, ECARO-25).
  • Reduction or isolation of oxygen: Representative agents: Argonite / IG-55 (ProInert),CO
    2carbon dioxide,Inert Gas 541IG-541 Inergen, and IG-100 (NN100).
  • Inhibiting the chain reaction of the above components. Representative agents:FE-13,1,1,1,2,3,3,3-Heptafluoropropane,FE-25,haloalkanes,bromotrifluoromethane,trifluoroiodomethane, NAF P-IV, NAF S-III, NAF S 125, NAF S 227, and Triodide (Trifluoroiodomethane)

Broadly speaking, there are two methods for applying an extinguishing agent: total flooding and local application:

  • Systems working on a total flooding principle apply an extinguishing agent to a three dimensional enclosed space in order to achieve a concentration of the agent (volume percent of the agent in air) adequate to extinguish the fire. These types of systems may beoperated automaticallyby detection and related controls or manually by the operation of a system actuator.
Request CallBack
Novec 1230 Fire Suppression
Get Best Quote

Novec 1230 Fire Suppression

Approx. Price: Rs 4.5 Lakh / SetGet Latest Price
Product Details:
Fire Extinguisher TypeClean agent gas based
CapacityDesign based
BrandTyco,sevo,kidde
Fire ClassC
MaterialCarbon Steel
Usage/ApplicationIndustrial
3M gas2-140 lit cylinders
Total room flooding system for power plant, server room, document area and office area. Novec gas based, 3M brand gas, UL approved gas and UL listed products.

Yes! I am Interested
Request CallBack
  • NOVEC System
  • NOVEC System
  • NOVEC System
NOVEC System
Get Best Quote

NOVEC System

Approx. Price: Rs 25,000 / SetGet Latest Price
Product Brochure
Product Details:
Fire Extinguisher TypeClean Agent Based
BrandAAG TRACE/Firetrace/ Firedetec/Firetec/CQRS/Tyco/Honeywell
Capacity1-140 Kg
Fire ClassA,B & C
MaterialSS & DOT
TypeSuppression System
UL Approved Novec 1230 gas based automatic fire suppression system. ( Tube Based & Total Flooding)

Yes! I am Interested
Request CallBack
  • Electrical Cabinet Fire System
  • Electrical Cabinet Fire System
  • Electrical Cabinet Fire System
  • Electrical Cabinet Fire System
Electrical Cabinet Fire System
Get Best Quote

Electrical Cabinet Fire System

Approx. Price: Rs 28,000 / SetGet Latest Price
Product Details:
Minimum Order Quantity5 Set
Fire ClassC, A, K, B
Fire Extinguisher TypeA B C Dry Powder Type, CO2 Based, Clean agent
Capacity4Kg, 2Kg, 3Kg, 4.5Kg
MaterialMetal alloy
CertificationISO, CE & UL, ISI
BrandFET/ Fire Finder
ConditionNew
FeaturesAutomatic Tubing Based
Usage/Applicationelectrical enclosure
Product TypeFire Extinguishers
ClassA, B, C & K
Operation Time In Seconds7-10 sec
Minimum Effective Discharge95 %
Time Of Extinguishing7-10 sec
Environment Temp68
Fire Suppression TypePipeline, Fire Extinguisher, Cylinder
TypeCylinder, Direct, Fire Extinguisher
Installation Services RequiredYes
Operating Temperature Limit90-120
Installation TypeYes
Working Pressure25 BAR
Cylinder Size4,6.9.22,34,45,80,120 and 140
Automation GradeAutomatic
Discharge RangePin Point
Maximum Service Pressure25 Bar
Types of Driven Gasclean agent
Is It PortablePortable
PortablePortable
Control HeadDLP
Chemical AgentNovec1230/ fm200/fe36
MountedWall/ Panel
Is It Eco FriendlyEco Friendly
Is It ISI CertifiedISI Certified
Anti Corrosive TreatmentYes
Confirming Is CodeYes
Extinguishing MediaGas
CertificateCE
Electrical Cabinet Fire System.
Flexible Polymer tube based automatic fire extinguishing system.

Additional Information:
  • Pay Mode Terms: L/C (Letter of Credit),T/T (Bank Transfer),D/P,D/A
  • Production Capacity: 500/ Month
  • Delivery Time: Ready Stock
Yes! I am Interested
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • Gas Fire Suppression
  • Gas Fire Suppression
  • Gas Fire Suppression
Gas Fire Suppression
Get Best Quote

Gas Fire Suppression

Approx. Price: Rs 35,000 / SetGet Latest Price
Product Details:
Minimum Order Quantity1 Set
Fire ClassC
FeaturesAUTOMATIC
Usage/ApplicationELECTRICAL pANELS
Class TypeA,B & c CLASS
Product TypeFIRE SUPPRESSION
Types of MountPanel/ Wall
ShapeCYLINDRICAL
Operation Time In Seconds10-15 SEC
Oparating ValveDLP
TypeFire Extinguisher, Cylinder, Direct
Fire Suppression TypeCylinder, Pipeline, Fire Extinguisher
Environment Temp65
Installation Services RequiredYes
CertificationISI
Installation TypeYes
Operating Temperature Limit90-120
ConditionNew
Discharge Time3-5 SEC
Capacity4Kg
Weight2,4,6,9
Storage Pressure35 BAR
Automation GradeAutomatic
Model NumberFETCA001
Spray Duration5 SEC
Discharge RangePIN POINT
Packaging TypeWOODEN
Suppression Systemautomatic
Burst Pressure25 BAR
DesignNFPA 2001
Valve MaterialBRASS
Types of Driven GasCLEAN AGENT
FormLIQUID
Temperature Range90-110
Operating Pressure25 BAR
ColorRed
BrandFire Engineering Technology
MaterialMetal alloy
Warranty3 Yrs
PortablePortable
Is It PortablePortable
Thermal ConductivityNO
Work LocationINDIA
Chemical AgentNovec 1230
Ce CertifiedCe Certified
Is It Eco FriendlyEco Friendly
Is It ISI CertifiedISI Certified
Confirming Is CodeYes
Conforming Is SpecnYES
Extinguishing MediaGas
Mounting BracketYES
Operation PositionON
Hydraulic Test Pressure35 BAR
Service Pressure25 BAR
Test Pressure35 BAR
Gasious fire suppression system

Additional Information:
  • Item Code: FETFE
  • Production Capacity: any
  • Delivery Time: 5 days
Yes! I am Interested