- Home
- ยป
- Products & Services
- »
- Fire suppression and Flooding systems
Fire suppression and Flooding systems
Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different applications being used today. Of these, there are some that are still in use but are no longer legal to manufacture and produce.[1]
Suppression systems[edit]Fire suppression systems are governed by the codes under the National Fire Protection Association, also known as the NFPA. This organization writes codes, regulations, and recommendations on the proper installation and maintenance of these fire suppression systems. Likewise, the NFPA also lists criteria that must be met for the requirements of certain types of fire suppression systems.[2]
Novec 1230 Fire Extinguisher System
Product Brochure
Capacity | 2 kg |
Fire Class | C |
Material | Mild Steel |
Usage/Application | Industrial |
Brand | Fire Engineering Technology |
Model Number | Novec 1230 |
We are one of the Biggest Manufacturers of Fire Suppression System. We Provide Pan India Service for Fire Suppression System. We have our happy clients who are totally satisfied with the quality of our Fire Suppression System. Our Fire Suppression System are of Heavy Build Quality. Our Fire Suppression System is certified by CE and UL .
Kitchen Fire Suppression System
Minimum Order Quantity: 1 Piece
Product Brochure
Agent | Wetchemical |
Fire Fighting System Type | Fire Extinguisher System |
Capacity | any |
Usage/Application | clean agent flooding system |
Color | red |
Certification | UL & CE |
Body Material | MS & SS |
Installation Services Required | yes |
Automation Grade | Automatic |
Design | NFPA |
Additional Information:
- Delivery Time: 5-10
UL Approve FK-5-1-12 Or Novec-1230 Gas
Minimum Order Quantity: 10 unit
Product Brochure
Type | Gas suppression systems |
Capacity | Any |
Usage/Application | Electrical Room, electrical panel, server room and all enclosed equipment |
Fire Extinguisher Type | Clean agent, Novec-1230, FK-5112, FM-200, HFC227EA |
Brand | FET FIREFINDER |
Color | red |
Certification | UL / FM/ CE/ LPCB |
Body Material | Steel Seamless |
Installation Services Required | yes |
Country of Origin | Made in India |
EXTINGUISHING METHOD FK-5-1-12 extinguishes a fire primarily through heat absorption. The gaseous mixture created when FK-5-1-12 discharges into air has a much higher heat capacity than air alone. The gaseous mixture absorbs large amounts of heat due to the high heat capacity and extinguishes fires by sufficiently cooling the combustion zone. It is important to note, FK-5-1-12 does not use the depletion of oxygen to extinguish a fire.
Class A & C: Electrical and Electronic Hazards Telecommunications Facilities High value assets, where the associated down-time would be costly
UL Approve FK-5-1-12 Or Novec-1230 GasIt is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration.
Direct Low-Pressure Clean Agent Systems
Minimum Order Quantity: 2 Piece
Product Brochure
Fire Class | A,B & C |
Material | Metal alloy |
Capacity | Any |
Fire Extinguisher Type | FK-5112 & DLP |
System Components | Fire detection Tube |
Type | Fully Automatic |
Usage/Application | Pre Engineered System |
Model Name/Number | 4000101 |
Alarm Volume | 100 DB |
Relay Outputs | Supervisory Relay |
Control Keys | System Reset |
AutoFireX® DLP- Direct Low-Pressure Clean Agent Systems are primarily Pre-Engineered Automatic Fire detection and suppression Systems utilising various Low-pressure Clean agents like,HFC227ea, FK 5-1-12, FE36. These Units are designed, manufactured, and tested in ISO 9001:2015 certified facilities.
The AutoFireX® Linear Pneumatic Fire Detection Tubing (LP-FDT) is installed and connected to DLP Valve via dual seal threaded union attached to the isolation ball valve and routed throughout the protected hazard area/enclosure. Being heat sensitive, the primary function of Linear Pneumatic Fire Detection Tube (under pressure) is to detect heat/fire and activate the valve for discharge of the agent by rupturing at the hottest point along its installed length on flame impingement. On rupture a nozzle is formed at the burst point.
Due to loss of the pressure in the tube, the clean agent under pressure, in the cylinder then flows out through the tube and discharged out at burst point/nozzle, extinguishing the fire instantly and flooding the protected enclosure, which helps in preventing reignition.
Each DLP system consists of a High-Grade Stainless-Steel Direct valve with integrated pressure gauge adaptor with Schrader valve on the valve body to monitor cylinder pressure, and a quarter turn isolation valve to interface with the AutoFireX® Fire Detection Tubing., and a PRD (Pressure Relief Device) tested up to 44Bar is also provided. The systems is supplied complete with CE Cylinders and Brackets Stainless steel siphon tube with appropriate agents, as required.
To assist in annunciation, an optional pressure switch provided, can be installed at one of the ports on valve or at the end of the detection line using End of Line Adaptor, also available with the system. The pressure switch provides a potential free contact, that can be interfaced, with existing FACP (Fire Alarm Control Panel) to indicate system discharge, shutdown ventilation, shut-off electrical power, as may be required. Alternatively, it can also be connected to a Audio Visual (A/V) alarm unit for annunciation.
Additional Information:
- Item Code: 4000101
- Production Capacity: 100
- Delivery Time: 2 week