Fire Suppression System Maharashtra
Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different applications being used today. Of these, there are some that are still in use but are no longer legal to manufacture and produce.[1]
Suppression systems[edit]Fire suppression systems are governed by the codes under the National Fire Protection Association, also known as the NFPA. This organization writes codes, regulations, and recommendations on the proper installation and maintenance of these fire suppression systems. Likewise, the NFPA also lists criteria that must be met for the requirements of certain types of fire suppression systems.[2]
Air Compressor Fire Suppression System
Product Brochure
Usage/Application | Industrial |
Type | Fire Suppression Systems |
Packaging Type | Set |
Capacity | As per requirement |
System type | Pre-Engineered System |
Brand | FET |
Material | Carbon Steel |
Environment Temp | 21 |
Fire Suppression Type | Cylinder, Fire Extinguisher, Pipeline |
Certification | CE & UL |
Wet suppression systems are not applicable in cold countries like Antarctica, Canada, Greenland, etc due to the freezing of pipes. In those countries, dry pipe systems are implemented. These systems use pressurized air or nitrogen to fill the pipes.
In case of fire, the sprinklers will break and due to this air escapes through the pipe and the dry pipe valve opens. At this stage, water starts flowing through the open pipes to suppress the fire. Dry pipe installations are designed in unheated warehouses and attics.NFPA 13, NFPA 13R, and NFPA 13D cover sprinkler installation procedures in colder areas.
The dry pipe system uses an air compressor to fill the system with air. If the pipes are leaking the air compressor should run and due to this moisture content increases. The formation of ice indicates air leaks. It needs a proper investigation to find the leak source and to repair it further. NFPA 13 requires the valves and piping to be kept at 40-degree Fahrenheit or above. The heat source of the valve room should be permanently installed. This installation of piping, valves, and accessories require highly trained engineers, technicians, and supervisors. The hands-on experience was provided on most modern technologies.