- Home
- ยป
- Products & Services
- »
- Fire Suppression System Bihar
Fire Suppression System Bihar
Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different applications being used today. Of these, there are some that are still in use but are no longer legal to manufacture and produce.[1]
Suppression systems[edit]Fire suppression systems are governed by the codes under the National Fire Protection Association, also known as the NFPA. This organization writes codes, regulations, and recommendations on the proper installation and maintenance of these fire suppression systems. Likewise, the NFPA also lists criteria that must be met for the requirements of certain types of fire suppression systems.[2]
Fm200 Fire Extinguishing System
Product Brochure
Usage/Application | Commercial |
Type | Fire Suppression Systems |
Packaging Type | Set |
Capacity | ANY |
System type | Pre-Engineered System |
Brand | FET |
Material | Mild Steel |
Environment Temp | 21 |
Fire Suppression Type | Pipeline, Fire Extinguisher, Cylinder |
Certification | UL/ FM/ LPCB/ CE |
Also known as HFC227ea, this is a waterless fire protection system that works wonders when under pressure. Within 10 seconds, it will discharge and suppress a fire immediately.
The product in an FM200 fire suppression system has also been found as an active compound as a propellant in medical inhalers. Needless to say, the gas is extremely safe when installed correctly.
When a fire breaks out in an intensely combustible area, the FM 200 reacts instantly to suppress the fire from spreading. The synthetic gas that makes up the FM 200 extinguishes the fire by removing the heat elements from the fire triangle. The fire triangle consists of oxygen, heat and fuel.
The FM 200 system has a typical concentration level between 7.9% to 8.5%, which is determined by the risk that is to be protected and the suggested level by the manufacturer.
The following environments could benefit from a suppression system:
- Airport Hangers
- Boat and Marine Applications
- Computer Server Rooms
- Fuel Stations
- Chemical Processes
- Flammable Liquid Storage Areas
- Power Generating Processes
- Switch Gear Rooms
- Cellular Sites
- Factories
- High Tech Medical Applications
- And many more!
Novec 1230 Gas Suppression System
Product Brochure
Fire Fighting System Type | Fire Suppression Systems |
Capacity | 58.5Kg |
Usage/Application | SERVER ROOM |
Pressure | 25 & 42 BAR |
No. of Cylinders | ANY |
Cylinder Height | ANY |
Cylinder Diameter | ANY |
Operating Temperature | 68 |
Coverage Area | 0.67/CUBIC MTR |
Nozzle Material | BRASS |
Novec 1230 fluid is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required. Each system consists of the following components and their associated accessories:
-
Agent Storage Components – Storage components consist of the cylinder assembly(s), which contains the Novec 1230 fluid, and the cylinder bracket(s), which holds the cylinder assembly securely in place.
-
Agent Fluid Distribution Components – Distribution components consist of the discharge nozzles used to introduce the Novec 1230 fluid into a protected hazard along with the associated piping system used to connect the nozzles to the cylinder assembly.
-
Trim Components – Trim components complete the installation of the suppression system and consist of connection fittings, pressure gauge, low-pressure supervisory switch, electric valve actuator, and manual valve actuator.
-
Slave Arrangement Components – Slave arrangement components consist of the pneumatic valve actuator(s), actuation check valve, vent check, actuation hose, and fittings required for a multiple cylinder (slave) arrangement.
-
Supplemental Components – Supplemental components include the discharge pressure switch and manifold check valve. They supplement the core equipment or complete a specific multicylinder configuration.
-
Control Panel – This device monitors the condition of the electric actuator, detectors, warning devices, cylinder pressure, and any manual release and abort stations. All electric or electronic devices must connect to the control panel in order to function.
-
Detection and Alarm Devices – Detection devices coupled with manual release and abort stations maximize system efficiency while audible and visual alarm devices alert staff of alarm conditions.
Gas Based Fire Suppression Systems
Product Brochure
Usage/Application | Industrial |
Fire Fighting System Type | Fire Suppression Systems |
Capacity | 1-9 |
Packaging Type | Set |
System type | Pre-Engineered System |
Brand | FET |
Material | Metal Alloy |
Environment Temp | 100 |
Fire Suppression Type | Cylinder, Fire Extinguisher, Pipeline |
Certification | UL & CE |
Novec 1230 fluid is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally occupied, in locations where clean-up of other agents is problematic, when storage space for a fire suppression agent is restricted, or when an electrically non-conductive agent is required. Each system consists of the following components and their associated accessories:
-
Agent Storage Components – Storage components consist of the cylinder assembly(s), which contains the Novec 1230 fluid, and the cylinder bracket(s), which holds the cylinder assembly securely in place.
-
Agent Fluid Distribution Components – Distribution components consist of the discharge nozzles used to introduce the Novec 1230 fluid into a protected hazard along with the associated piping system used to connect the nozzles to the cylinder assembly.
-
Trim Components – Trim components complete the installation of the suppression system and consist of connection fittings, pressure gauge, low-pressure supervisory switch, electric valve actuator, and manual valve actuator.
-
Slave Arrangement Components – Slave arrangement components consist of the pneumatic valve actuator(s), actuation check valve, vent check, actuation hose, and fittings required for a multiple cylinder (slave) arrangement.
-
Supplemental Components – Supplemental components include the discharge pressure switch and manifold check valve. They supplement the core equipment or complete a specific multicylinder configuration.
-
Control Panel – This device monitors the condition of the electric actuator, detectors, warning devices, cylinder pressure, and any manual release and abort stations. All electric or electronic devices must connect to the control panel in order to function.
-
Detection and Alarm Devices – Detection devices coupled with manual release and abort stations maximize system efficiency while audible and visual alarm devices alert staff of alarm conditions.