- Home
- ยป
- Products & Services
- »
- Novec 1230 Fire Suppression System
Novec 1230 Fire Suppression System
Global power consumption accelerated in 2018 by 3.5 percent. Each year the demand for electricity increases, and we put more and more demand on the electrical grid. Outdated infrastructure, poor maintenance, faulty wires, and overloaded circuits are all risk factors for electrical fires. Electrical panels are critical to the business operations and are susceptible to fire hazards. Ourautomatic fire suppression systemscan detect and suppress the fire before it grows, minimizing damage to the panel.
About Automatic Fire Suppression systems
Electrical cabinets power machinery and equipment for all types of manufacturing facilities. Production stops if there is an interruption to the electrical supply. Power outages occur from storms, wildlife, tree limbs, and equipment failure. When a failure occurs in the electrical cabinet, it can lead to a fire. Overloaded circuits and old wiring cause arching, creating a fire hazard. An automatic fire suppression system quickly detects and suppresses the fire to minimize damage to the electrical cabinet allowing the facility to get back up and running.
Novec 1230 Fire Suppression System for Electrical Panels, Novec 1230 Fire Suppression System for Server room, Novec 1230 Fire Suppression System HT Panels, Novec 1230 Fire Suppression System for PCC Panels, Novec 1230 Fire Suppression System.
Novec 1230 Fire Suppression System,
Novec 1230 Fire Suppression System,
Novec 1230 Fire Suppression System,
Novec 1230 Fire Suppression System,
Novec 1230 Fire Suppression System.
Novec 1230 Fire Suppression System - 42 Bar
Product Brochure
Type | 42 Bar Novec 1230 System |
Capacity | Any |
Usage/Application | Electrical Room, electrical panel, server room and all enclosed equipment |
Fire Extinguisher Type | Clean agent - Novec-1230, FK-5112, FM-200, HFC227EA |
Brand | TYCO/ Sapphire |
Color | red |
Certification | UL & VDS |
Body Material | ISI/ PESO/ UL/ DOT |
Installation Services Required | yes |
Overview HYGOOD SAPPHIRE Fire Suppression Systems delivering 3M™ Novec™ 1230 Fire Protection Fluid is a safe, environmentally friendly clean agent system, that has a proven track record for protecting people and high value assets. Protecting our world HYGOOD SAPPHIRE systems provide a proven and reliable fast acting, clean agent solution that is safe for use in occupied spaces. The system is environmentally friendly with zero ozone depletion potential (ODP) and negligible global warming potential (GWP). The atmospheric lifetime is between three and five days making HYGOOD SAPPHIRE an ideal solution without compromising the environment. Every HYGOOD SAPPHIRE installation carries a 20 year environmental warranty covering both the agent and the system hardware. See table overleaf for a comparison of the environmental credentials of common halocarbon clean agent systems Playing safe HYGOOD SAPPHIRE systems are ideal for use in occupied areas. Independent toxicity studies have established that the agent is low in both acute and chronic toxicity with high safety margins between its normal use concentrations and the No Observable Adverse Effect Level (NOAEL). Fast acting suppression HYGOOD SAPPHIRE systems work fast and are designed to rapidly absorb heat to the point where combustion ceases. Once actuated, HYGOOD SAPPHIRE systems deliver the extinguishant within 10 seconds, suppressing fires before they have the chance to spread. Most importantly when a fire is suppressed quickly, the result is less damage, lower refurbishment costs and reduced downtime.
Compact low pressure technology HYGOOD SAPPHIRE systems are compact and operate at both 25 and 42 bar and have been designed and developed based on independently witnessed fire tests. It has been proven to achieve homogeneous distribution of agent at these pressures complying with international standards and meeting the requirements of approval agencies worldwide. System recharging As the Novec 1230 Fluid is stored as a liquid at room temperature the agent may be transported in lightweight drums or plastic totes, enabling the agent to be made available quickly at a conveniently located recharge station. 25 and 42 bar options The HYGOOD SAPPHIRE System is available in both 25 and 42 bar pressures. The 25 bar system is suitable for the majority of hazards whilst the 42 bar offers additional flexibility in the design of systems, protecting larger or more complex hazards, including those incorporating selector valves for multi-zone protection and where system containers are to be located further from the protected hazard.
Novec 1230 Fire Protection System
Product Brochure
Type | Fire Extinguisher |
Capacity | Any |
Usage/Application | Fire Safety |
Fire Extinguisher Type | Clean agent - Novec-1230, FK-5112, FM-200, HFC227EA |
Material | UL Approved Gas, Mild Steel |
Color | Red |
Finishing | Polished |
Brand | FET FIREFINDER |
Mounting | Wall Mounting |
Electrical Panel Gas Flooding System
Product Brochure
Usage/Application | Electrical Panel |
Type | gas Suppression system |
Capacity | 5 LBS |
Packaging Type | Box |
Fire Extinguisher Type | Automatic Fire suppression Extinguishers |
Brand | FET FIREFINDER |
Material | Metal Alloy |
Environment Temp | 21 Degree C |
Operating Temperature Limit | 120 Degree C |
Working Pressure | 15 Bar |
Model Number | ARFSS01 |
Other Detail:
- Filled container fitted with DLP Valve and Pushin connecter.
- Specially design bracket for cylinder.
- Fire detection tube
- End of line adopter
- Pressure Switch
- Hooter
- Note Supply only.
Electrical Cabinate Fire Suppression System - Novec-1230
Product Brochure
Type | Cylinder |
Brand | Fire Engineering Technology |
Capacity | 4 kg |
Fire Class | C |
Usage/Application | Commercial |
Material | Carbon Steel |
Environment Temp | 21 Degree C |
FIRE SUPPRESSION SYSEM
Product Brochure
Fire Fighting System Type | Fire Suppression Systems |
Usage/Application | Industrial |
Capacity | 5 LB/ 2KG |
System type | Pre-Engineered System |
Brand | FET FIREFINDER |
Material | Mild Steel |
Environment Temp | 21 |
Fire Suppression Type | Fire Extinguisher, Cylinder |
Certification | CE |
2 kg capacity NOVEC 1230 / FK-5112 UL Approved , DLP assembly with automatic valve, push in connector for tube, 2 Kg gas, mounting bracket, Make : AR Suppression/ FET Firefinder/ FIRE ENGINEERING TECHNOLOGY
|
Server Room Novec 1230 gas flooding system
Product Brochure
Fire Suppression Type | Fire Extinguisher |
Fire Fighting System Type | Fire Suppression Systems |
Capacity | 80 LIT |
Usage/Application | SERVER ROOM |
Extinguishing Agent | NOVEC 1230 |
Brand | TYCO |
Color | RED |
Cylinder Height | AS PER SIZE |
Design | NFPA 2001 AND VDS |
Discharge Range | 2 MTR |
Gas Flooding Systems are typically used in protecting the critical areas like Control Room, Data Center, Server Room, MCC or PCC Room using Gas Flooding System. Gas Flooding Systems make use of gases like Sinorix 227 (also referred to as FM200 or HFC 227), Novec 1230 (also referred to as Novec 1230) , CO2 or Inert Gases.
FIRE ENGINEERING TECHNOLOGY provides turnkey solutions (design, supply, installation and commissioning). Our technical staff have extensive experience in installation of gas flooding system and offer expert installation.
Server Room Novec 1230 gas flooding system,
Server Room Novec 1230 gas flooding system,
Server Room Novec 1230 gas flooding system,
Server Room Novec 1230 gas flooding system,
Server Room Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system,
MCC ROOM Novec 1230 gas flooding system.
Fm 200 Gas Based Fire Suppression Systems
Product Brochure
Fire Fighting System Type | Fire Suppression Systems |
Usage/Application | Commercial |
Capacity | 1,2,4,6 AND 9 KG |
Packaging Type | Set |
System type | Pre-Engineered System |
Brand | FIRETRACE |
Material | Carbon Steel |
Environment Temp | 21 |
Fire Suppression Type | Pipeline, Fire Extinguisher, Cylinder |
Certification | UL |
FM-200 fire suppression system,
FM-200 fire suppression system,
FM-200 fire suppression system,
FM-200 fire suppression system,
FM-200 fire suppression system,
HFC227 GAS BASED fire suppression system,
HFC227 GAS BASED fire suppression system,
HFC227 GAS BASED fire suppression system,
HFC227 GAS BASED fire suppression system,
HFC227 GAS BASED fire suppression system,
HFC227 GAS BASED fire suppression system.